import logging
import requests
from borgmatic.hooks import monitor
logger = logging.getLogger(__name__)
MONITOR_STATE_TO_CRONITOR = {
monitor.State.START: 'run',
monitor.State.FINISH: 'complete',
monitor.State.FAIL: 'fail',
}
def initialize_monitor(
ping_url, config_filename, monitoring_log_level, dry_run
): # pragma: no cover
'''
No initialization is necessary for this monitor.
'''
pass
def ping_monitor(ping_url, config_filename, state, monitoring_log_level, dry_run):
'''
Ping the given Cronitor URL, modified with the monitor.State. Use the given configuration
filename in any log entries. If this is a dry run, then don't actually ping anything.
'''
dry_run_label = ' (dry run; not actually pinging)' if dry_run else ''
ping_url = '{}/{}'.format(ping_url, MONITOR_STATE_TO_CRONITOR[state])
logger.info(
'{}: Pinging Cronitor {}{}'.format(config_filename, state.name.lower(), dry_run_label)
)
logger.debug('{}: Using Cronitor ping URL {}'.format(config_filename, ping_url))
if not dry_run:
logging.getLogger('urllib3').setLevel(logging.ERROR)
requests.get(ping_url)
def destroy_monitor(
ping_url_or_uuid, config_filename, monitoring_log_level, dry_run
): # pragma: no cover
'''
No destruction is necessary for this monitor.
'''
pass